6.71mmpb 25mm Radiation Resistant Protection Lead Glass Xray ECT Room

Place of Origin China
Brand Name Jovi
Certification CE
Model Number 1-CF-15
Minimum Order Quantity 1 PC
Price USD200-2167/PC
Packaging Details Wrapped in kraft paper, then packed in wooden case. Size according to lead glass size, usually 5 pcs per case.
Delivery Time 5-8 work days
Payment Terms L/ C, T/ T, Western Union
Supply Ability 3000PCS per month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Thickness 8/ 10/ 12/ 15/ 18/ 20/ 23/ 25mm Lead Equivalent 1.7/ 2.1/ 2.6/ 3.3/ 3.96/ 4.4/ 6.71mmpb
MOQ 1 Pc Color Transparent
Function Xray Protection Shape Circle, Square And Customized
Highlight

6.71mmpb Radiation Protection Lead Glass

,

25mm Radiation Protection Lead Glass

,

radiation resistant glass Xray ECT room

Leave a Message
Product Description

Xray CT ECT PET Installation Material Radiation Protection Lead Glass

 

Quick Detail:

 · Size from 200 * 300mm to 1200 * 2400mm

 · Customized Size accepted

 · Thickness 8/ 10/ 12/ 15/ 18/ 20/ 23/ 25mm

 · Lead equivalent 1.7/ 2.1/ 2.6/ 3.3/ 3.96/ 4.4/ 5.8/ 6.71mmpb

 · Stainless Steel and Aluminium frame available

 · Packing in wooden case

 · Low MOQ

 · CE Certificate

 

 

Specification: 

 

  8mm 10mm 12mm 15mm 18mm 20mm 25mm
( 1.7mmpb) ( 2.1mmpb) ( 2.6mmpb) ( 3.3 mmpb) ( 3.96 mmpb) ( 4.4 mmpb) ( 6.71 mmpb)
200* 300 200* 300* 8 200* 300* 10 200* 300* 12 200* 300* 15 200* 300* 18 200* 300* 20 -
300* 400 300* 400* 8 300* 400* 10 300* 400* 12 300* 400* 15 300* 400* 18 300* 400* 20 -
400* 600 400* 600* 8 400* 600* 10 400* 600* 12 400* 600* 15 400* 600* 18 400* 600* 20 -
600* 800 600* 800* 8 600* 800* 10 600* 800* 12 600* 800* 15 600* 800* 18 600* 800* 20 -
600* 900 600* 900* 8 600* 900* 10 600* 900* 12 600* 900* 15 600* 900* 18 600* 900* 20 -
1000* 800 1000* 800* 8 1000* 800* 10 1000* 800* 12 1000* 800* 15 1000* 800* 18 1000* 800* 20 1000* 800* 25
1200* 800 1200* 800* 8 1200* 800* 10 1200* 800* 12 1200* 800* 15 1200* 800* 18 1200* 800* 20 1200* 800* 25
1200* 900 1200* 900* 8 1200* 900* 10 1200* 900* 12 1200* 900* 15 1200* 900* 18 1200* 900* 20 1200* 900* 25
1200* 1000 1200* 1000* 8 1200* 1000* 10 1200* 1000* 12 1200* 1000* 15 1200* 1000* 18 1200* 1000* 20 1200* 1000* 25
1200* 1200 - 1200* 1200* 10 1200* 1200* 12 1200* 1200* 15 1200* 1200* 18 1200* 1200* 20 1200* 1200* 25
1500* 900 - 1500* 900* 10 1500* 900* 12 1500* 900* 15 1500* 900* 18 1500* 900* 20 1500* 900* 25
1500* 1000 - 1500* 1000* 10 1500* 1000* 12 1500* 1000* 15 1500* 1000* 18 1500* 1000* 20 1500* 1000* 25
1500* 1200 - 1500* 1200* 10 1500* 1200* 12 1500* 1200* 15 1500* 1200* 18 1500* 1200* 20 1500* 1200* 25
1600* 1000 - 1600* 1000* 10 1600* 1000* 12 1600* 1000* 15 1600* 1000* 18 1600* 1000* 20 1600* 1000* 25
1600* 1200 - 1600* 1200* 10 1600* 1200* 12 1600* 1200* 15 1600* 1200* 18 1600* 1200* 20 1600* 1200* 25
1800* 1000 - 1800* 1000* 10 1800* 1000* 12 1800* 1000* 15 1800* 1000* 18 1800* 1000* 20 1800* 1000* 25
1800* 1200 - 1800* 1200* 10 1800* 1200* 12 1800* 1200* 15 1800* 1200* 18 1800* 1200* 20 1800* 1200* 25
2000* 1000 - 2000* 1000* 10 2000* 1000* 12 2000* 1000* 15 2000* 1000* 18 2000* 1000* 20 2000* 1000* 25
2000* 1200 - 2000* 1200* 10 2000* 1200* 12 2000* 1200* 15 2000* 1200* 18 2000* 1200* 20 2000* 1200* 25
2400* 1200 - 2400* 1200* 10 2400* 1200* 12 2400* 1200* 15 2400* 1200* 18 2400* 1200* 20 2400* 1200* 25


6.71mmpb 25mm Radiation Resistant Protection Lead  Glass Xray ECT Room 0

Application:

Lead glass is mainly used in the manufacturing of optical instruments, art vessels, etc.

Lead glass is also known as medical X-ray radiation-proof lead glass plate in the medical field.

Lead glass is mainly used for diagnostic X-ray machine rooms, CT, ECT, PET, ct-pet and other machine rooms,

as well as observation Windows on the protective screen of protective doors.

 

Notices:

 1. Lead glass is a brittle material with a large proportion, so it must be handled gently when it is moved.

 2. When installation, the glass must be mismatched with the wall protection material to prevent radiation

leakage at the joint.

 3. As lead glass materials are rich in lead and barium, lead glass is easy to be contaminated by acid and base,

   and is not easy to be installed or stored in a sour or humid environment.

 4. The surface of lead glass is more easily scratched than that of ordinary glass and should be handled with care.

 

FAQ:

8/10/12/15/18/20/23/25mm Thickness Xray CT Room Installation Material Lead Glass

 

Q1. Can I have a sample order for lead glass?

A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

 

Q2. What about the lead time?

A: Usually 5-7 working days.

 

Q3. How do you ship the goods and how long does it take to arrive?

A: Ship by Air and Sea. 

 

Q4. How to proceed an order for lead glass?

A: Firstly let us know your requirements or size, thickenss and also quantity.

Secondly We quote according to your requirements or our suggestions.

Thirdly customer confirms.

Fourthly We arrange the production.