-
Copper Foil Shielding
-
RF Shielded Doors
-
RF Shielded Windows
-
Radiation Protection Lead Glass
-
Non Magnetic Tool Kit
-
Nuclear Radiation Protection
-
Nuclear Radiation Detector
-
RF Shielded Chamber
-
Honeycomb Waveguide Air Vents
-
Conductive Adhesive Copper Tape
-
Copper Wire Mesh
-
X Ray Lead Glass
-
EMI Shielding Gasket
-
Electrically Conductive Fabric
-
Radiation Protection Door
-
Radiation Protection X Ray
-
Faraday Cage MRI
-
MRI LED Lighting
-
Copper Wire Wool
-
Non Magnetic Wheelchair
-
Non Magnetic Stretcher
-
AnasBrass honeycomb vent Looks Very Nice
-
SatheeshMRI/RF doors are shining with handles, Thank you My friend.
20 Mm Thickness Radiation Protection Lead Glass 4.4 Mmpb Lead Equivalence X Ray
Place of Origin | China |
---|---|
Brand Name | Jovi |
Certification | CE |
Model Number | 1-CF-15 |
Minimum Order Quantity | 2 pcs lead glass |
Price | USD 1980-2680/pcs |
Packaging Details | in piece and in wooden case |
Delivery Time | within 7-10 days after receiving payment |
Payment Terms | L/C, T/T, Western Union |
Supply Ability | 3500 pcs per month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | 20 Mm Thickness 4.4 MmPb Lead Equivalence X-Ray Radiation Protection Lead Glass | Lead Equivalent | 4.4mmPb |
---|---|---|---|
Thickness | 20mm | Color | Transparent Glass Color |
Application | Xray Room CT Room | Shape | Square |
Highlight | radiation protection lead glass x ray,4.4 mmpb radiation protection lead glass,20 mm thickness radiation shielding glass |
20 mm Thickness 4.4 mmPb Lead Equivalence X-Ray Radiation Protection Lead Glass
Quick Detail:
· Available with lead-lined telescoping frames for walls or lead-lined vision frames for doors
· Many x-ray protective shielding levels are available
· With frame and without frame both available
· Over 50 standard sizes up to 96" x 48"
· Lead equivalent 2.1mm Pb
· Safety-rated impact resistant or laminated available upon request
· 3-day standard fabrication
Description:
The function of lead glass:
the main performance of lead glass is optically clear and transparent protective shielding.
A low optical quality protective glass plate with prescribed attenuation performance is used,
and its attenuation performance is 0.22mmpb per millimeter; applicable scope It can be installed
in the observation window laboratory of X-ray detection and CT scanning.
The lens of the protective window goggles.
The X-ray screen of the airport security inspection and the protective window for industrial flaw detection.
In radiology medicine, it is often used for radiation protection and shielding, or Observation window for the lead room for filming.
According to the different lead content, lead glass mainly has four series: ZF2, ZF3, ZF6, and ZF7.
Currently, ZF2 series lead glass is generally used. The high lead glass of the ZF6 and ZF7 series has high lead content and the same thickness. The amount of protection is high and the weight is large.
ZF series high-lead glass products adopt advanced production technology and optical detection methods.
The materials are made of high-lead content optical glass. They have the characteristics of clean internal materials, good transparency, large lead equivalent, and strong anti-radiation ability. , It can effectively block X-rays, gamma rays, cobalt 60 rays, and isotope scanning.
ZF2, ZF3 series of high-lead glass is widely used in X-ray diagnosis and spiral CT scanning room observation window, medical diagnostic shielding; ZF6, ZF7 series of high-lead glass is mainly used in nuclear power plants, nuclear energy applications, and other nuclear industries.
We supply radiation-proof lead glass, Radiation shielding sheets, and lead screens, and Lead sheets are mainly used for radial protection and shielding protection.
and our sale lines also include lead glass doors, lead glass windows,lead glass pipes, lead wires, and barium sulfates, etc. The radiation protection lead glass sheet is one of the high-teach ionizing radiation protection products. The Pb equivalent of the lead glass sheets are including 1mmPb, 2mmPb, 3mmPb, 4mmPb, 5mmPb, 6mmPb, 8mmPb, and so on.
and the sizes of the lead glass sheets are according to the customer's requirements. The product features excellent radiation protection performance. as well as the perfect match between visual effect and high-quality medical equipment. so, it is really an ideal quality product applicable to radiology rooms for such equipment as linear accelerators, gamma knives,post-loading equipment, PET-CT, CT, DR, MRI, DSA, and X-ray machines in modern high-grade hospitals.
the lead glass sheets have specific gravity, it should be taken care of during the course of movement.
Specification:
Equivalent | |||
Standard Thickness Glass | |||
Lead Glass(mmPb) | 1.8-2.0 | 2.5-2.7 | 3.0-3.2 |
Thickness(mm) | 9-10 | 11-12 | 14-15 |
X-Ray peak voltage(kv) | 150 | 150 | 200 |
We can offer different and customized sizes of lead glass for X-ray and CT Room installation.
Indeed we can also offer a lead door for shielding materials.
8mm (1.7mmpb) |
10mm (2.1mmpb) |
12mm (2.6mmpb) |
15mm (3.3 mmpb) |
18mm (3.96 mmpb) |
20mm (4.4 mmpb) |
25mm (6.71 mmpb) |
|
200*300 | 200*300*8 | 200*300*10 | 200*300*12 | 200*300*15 | 200*300*18 | 200*300*20 | - |
300*400 | 300*400*8 | 300*400*10 | 300*400*12 | 300*400*15 | 300*400*18 | 300*400*20 | - |
400*600 | 400*600*8 | 400*600*10 | 400*600*12 | 400*600*15 | 400*600*18 | 400*600*20 | - |
600*800 | 600*800*8 | 600*800*10 | 600*800*12 | 600*800*15 | 600*800*18 | 600*800*20 | - |
600*900 | 600*900*8 | 600*900*10 | 600*900*12 | 600*900*15 | 600*900*18 | 600*900*20 | - |
1000*800 | 1000*800*8 | 1000*800*10 | 1000*800*12 | 1000*800*15 | 1000*800*18 | 1000*800*20 | 1000*800*25 |
1200*800 | 1200*800*8 | 1200*800*10 | 1200*800*12 | 1200*800*15 | 1200*800*18 | 1200*800*20 | 1200*800*25 |
1200*900 | 1200*900*8 | 1200*900*10 | 1200*900*12 | 1200*900*15 | 1200*900*18 | 1200*900*20 | 1200*900*25 |
1200*1000 | 1200*1000*8 | 1200*1000*10 | 1200*1000*12 | 1200*1000*15 | 1200*1000*18 | 1200*1000*20 | 1200*1000*25 |
1200*1200 | - | 1200*1200*10 | 1200*1200*12 | 1200*1200*15 | 1200*1200*18 | 1200*1200*20 | 1200*1200*25 |
1500*900 | - | 1500*900*10 | 1500*900*12 | 1500*900*15 | 1500*900*18 | 1500*900*20 | 1500*900*25 |
1500*1000 | - | 1500*1000*10 | 1500*1000*12 | 1500*1000*15 | 1500*1000*18 | 1500*1000*20 | 1500*1000*25 |
1500*1200 | - | 1500*1200*10 | 1500*1200*12 | 1500*1200*15 | 1500*1200*18 | 1500*1200*20 | 1500*1200*25 |
1600*1000 | - | 1600*1000*10 | 1600*1000*12 | 1600*1000*15 | 1600*1000*18 | 1600*1000*20 | 1600*1000*25 |
1600*1200 | - | 1600*1200*10 | 1600*1200*12 | 1600*1200*15 | 1600*1200*18 | 1600*1200*20 | 1600*1200*25 |
1800*1000 | - | 1800*1000*10 | 1800*1000*12 | 1800*1000*15 | 1800*1000*18 | 1800*1000*20 | 1800*1000*25 |
1800*1200 | - | 1800*1200*10 | 1800*1200*12 | 1800*1200*15 | 1800*1200*18 | 1800*1200*20 | 1800*1200*25 |
2000*1000 | - | 2000*1000*10 | 2000*1000*12 | 2000*1000*15 | 2000*1000*18 | 2000*1000*20 | 2000*1000*25 |
2000*1200 | - | 2000*1200*10 | 2000*1200*12 | 2000*1200*15 | 2000*1200*18 | 2000*1200*20 | 2000*1200*25 |
2400*1200 | - | 2400*1200*10 | 2400*1200*12 | 2400*1200*15 | 2400*1200*18 | 2400*1200*20 | 2400*1200*25 |
Notices:
1. The surface of lead glass is more easily scratched than that of ordinary glass and should be handled with care.
2. As lead glass materials are rich in lead and barium, lead glass is easy to be contaminated by acid and base,
and is not easy to be installed or stored in a sour or humid environment.
3. When installation, the glass must be mismatched with the wall protection material to prevent radiation leakage at the joint.
4. Lead glass is a brittle material with a large proportion, so it must be handled gently when it is moved.
Application:
It is mainly used for diagnostic X-ray machine rooms, CT, ECT, PET, ct-pet, and other machine rooms,
as well as observation of Windows on the protective screen of protective doors.
It is mainly used in manufacturing optical instruments, art vessels, etc.
It is also a medical X-ray radiation-proof lead glass plate in the medical field.
FAQ:
Q1. Can I have a sample order for lead glass?
A: Yes, we welcome sample orders to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?
A: Usually 5-7 working days.
Q3. Do you have any MOQ limit for led light orders?
A: Low MOQ, 1pc is available.
Q4. How do you ship the goods and how long does it take to arrive?
A: Ship by Air and Sea.
Q5. How to proceed with an order for lead glass?
A: Firstly let us know your requirements or size, thickness and also quantity.
Secondly, We quote according to your requirements or our suggestions.
Thirdly customer confirms.
Fourthly We arrange the production.
Q6. Is it OK to print my logo on the product?
A: We can offer a sticky label on a wooden case with OEM service.