-
Copper Foil Shielding
-
RF Shielded Doors
-
RF Shielded Windows
-
Radiation Protection Lead Glass
-
Non Magnetic Tool Kit
-
Nuclear Radiation Protection
-
Nuclear Radiation Detector
-
RF Shielded Chamber
-
Honeycomb Waveguide Air Vents
-
Conductive Adhesive Copper Tape
-
Copper Wire Mesh
-
X Ray Lead Glass
-
EMI Shielding Gasket
-
Electrically Conductive Fabric
-
Radiation Protection Door
-
Radiation Protection X Ray
-
Faraday Cage MRI
-
MRI LED Lighting
-
Copper Wire Wool
-
Non Magnetic Wheelchair
-
Non Magnetic Stretcher
-
AnasBrass honeycomb vent Looks Very Nice
-
SatheeshMRI/RF doors are shining with handles, Thank you My friend.
Real Time Neutron Radiation Monitoring Dosimeter For Nuclear Power Plants

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xEnergy Range | Neutron0.025eV~16MeV; | Measuring Range Of The Neutron Dose Rate0.1μSv/h~100mSv/hMeasuring Range Of The Neutron Dose Rate | 0.1μSv/h~100mSv/h |
---|---|---|---|
Relative Inherent ErrorRelative Inherent Error | ±15%; | Neutron SensitivityNeutron Sensitivity | Greater Than1.4CPS/μSv/h |
γ Sensitivity | The No-response Threshold Is Not Lower Than 25μGy/hγ Sensitivity:the No-response Threshold Is Not Lower Than 25μGy/h | Weight | 9.8Kg; |
Sizze | 350*250*245(mm) | ||
Highlight | Real Time Neutron Radiation Monitoring Dosimeter,Nuclear Power Plants Radiation Monitoring Dosimeter,Nuclear Power Plants Radiation Detector |
Neutron Dosimeter | |||
|
Model | JV-1021 | |
1021Neutron dosimeter is used for continuous monitoring of environmental neutron radiation.It can also be connected with multiple neutron dosimeters to monitor neutron Radiation in a specific area,so as to provide The radiation dose rate value in the environment in real time and provide data basis for the management decision of the monitoring center.Can send out sound and light alarm signal according to the predetermined alarm threshold to warn the field staff and ensure their safety.The instrument is imported with high sensitivity 3 He-tube with large size polyethylene ball as a detector,fast reaction speed and good γresistance.
|
|||
Technical Description | Application | ||
1.Suitable for neutron radiation on line dose rate monitoring and alarm in nuclear radiation applications; |
The instrument is suitable for accelerator room,environmental protection,chemical industry, petroleum, medical treatment,import and export commercial inspection,nuclear power, neutron source and other security check, border control,customs inspection and other neutron radiation detection occasions. |
||
2.Use 3-He-tube with large volumes low for better energy response and sensitivity; | |||
3. With the upper computer software communication interface,it can be fixed and installed in the radiation application site to be monitored. | |||
4.Through wireless or the wired network summarizes the real-time dose rate,information into the monitoring computer system to for ma regional radioactivity monitoring network; | |||
5.It can be used alone and flexibly placed in the office or carried around; | |||
6.It can set the alarm threshold by yourself,and output the alarm signal through the field sound and optical alarm; | |||
7.Equipped with a large-size high-definition touch screen,real-time display of measurement value,measurement unit and other information; | |||
8.With the backup battery,keep the equipment to continue to work for no less than 8hours when the power is cut off; | |||
9.Energy range:neutron0.025eV~16MeV; | |||
10.Measuring range of the neutron dose rate:0.1μSv/h~100mSv/h; | |||
11.Relative inherent error:±15%; | |||
12.Neutron sensitivity:greater than1.4CPS/μSv/h; | |||
13.γ sensitivity:the no-response threshold is not lower than 25μGy/h; | |||
14.Use environment:temperature-15℃~+50℃,relative humidity(at40℃temperature)95%; | |||
15.Protection level:IP65; | |||
16.Weight and size:about350250245(mm),about9.8Kg; | |||
17.Accessories:supporting charger,suitcase/strap,etc. |